List of Recent Software Limited Releases

List of Recent Software Limited Releases

Product Name

Date

Version
Number

Resolved Issue(s)

MatrikonOPC Tunneller May 25, 2017 5.5.2.6912 New Features and Enhancements:
  • 23568: Tunneller CSC periodically checks the license on the SSC and updates statistical items on the CSC reflecting the SSC license status. Previously the frequency was hard-coded to 6 seconds. The frequency, in milliseconds, is now configurable in file TunnellerOpts.ini in the Tunneller directory in (new) section TSLicense item SSCLicenseCheckTime. Sections are seen in this file delimited by [ ] and items are seen as item=value, for example:
    [TSLicense]
    ; How often the CSC checks the SSC license status, in milliseconds.
    SSCLicenseCheckTime=5000
    The default value has been changed from 6000 to 60000.
    If the value is set to 0 then the CSC will never check the SSC license status and the associated OPC items will stay at Q_BAD.
MatrikonOPC Server for PROVOX Direct May 23, 2017 1.3.0.5.RC1 Resolved Issues:
  • 20545: EDCD Enhanced items do not update except by demand read.
MatrikonOPC Server for SCADA CAC May 10, 2017 3.0.1 Resolved Issues:
  • Float data type not reading correctly
MatrikonOPC Funnel May 01, 2017 3.1.0.6888 New Features and Enhancements:
  • Now supports Windows 10, Windows 2012, and Windows 2016.
Resolved Issues:
  • 21628: Unsolicited update will not occur after demand read if the new unsolicited value matches the previous unsolicited value sent.
MatrikonOPC Server for SCADA IEC60870 Apr 20, 2017 1.0.5.3 Resolved Issues:
  • 18401: OPC server should terminate communication if send/receive counter is out of sync.
  • 20551: Program needs to deal with unsolicited messages being received while a command is outstanding.
MatrikonOPC Server for AllenBradleyPLCs Apr 10, 2017 4.1.0.6869 Resolved Issues:
  • 19248: BOOL array reads do not work correctly for firmwares above 20.
  • 19255: This fix for firmware 20 reads was found to be defective and reverted.
  • 23049: BOOL array writes do not work.
MatrikonOPC Server for Foxboro DCS Apr 4, 2017 4.1.1.0 Resolved Issues:
  • 0020550: Need to detect CPs of type Cxxx.
MatrikonOPC Server for AllenBradleyPLCs Mar 27, 2017 4.0.5.6844 Resolved Issues:
  • 22560: Accessing bits from an array item, e.g. MyInt[7].VALUE/12 does not work correctly for firmwares above 20.
MatrikonOPC Server for Citect Mar 24, 2017 4.1.0.6844 New Features and Enhancements:
  • Support added for Windows 10, Windows 2012, and Windows 2016.
Resolved Issues:
  • 22624: Citect API throws exception when broken Citect connection is closed.
MatrikonOPC Server for IP21 Mar 20, 2017 2.4.0.6841 New Features and Enhancements:
  • Now supports Windows 10 and Windows 2016.
Resolved Issues:
  • 0021412: OPC server may not correctly use selector records for custom records.
MatrikonOPC 
Redundancy Broker (ORB)
Mar 16, 2017 4.3.0.6838 New Features and Enhancements:
  • Windows 2016 is now supported.
Resolved Issues:
  • 18383: When a multi-threaded client connects to several different ORB connections at the same time, all of the threads will connect to the same ORBed pair.
MatrikonOPC Server for AllenBradley PLCs Jan 25, 2017 4.0.4 Resolved Issues:
  • 19255: Firmware 20 array reads off by 4 bytes.
MatrikonOPC Server for SCADA Modbus Dec 22, 2016 2.0.2.6753 Resolved Issues:
  • 0021274: Demand reading a Slave device link causes it to permanently go to a communications failure state.
MatrikonOPC Data Manager Dec 19, 2016 6.0.3.6 Enhancements:
  • An registry option has been added to remove group deactivation when rebuilding groups. Set HKEY_CLASSES_ROOT\Matrikon DataManager\Options item DeactivateGroups to a String value equal to numerical 0 to not deactivate groups when rebuilding groups. Any other value will use the default, which is to deactivate groups when rebuilding them.
MatrikonOPC Server for Wonderware Historian Sept 22, 2016 2.0.1.6652 ​

Resolved Issues:

  • 0018437: OPC server should split up writes of over 990 values into many writes of 990 values each, otherwise they will fail.
  • 0018438: OPC server should write a NULL value if an empty string is written.
MatrikonOPC Server for Siemens Wind Turbines Sept 6, 2016 1.0.3.6638

Resolved issues:

  • 20532: OPC server sometimes does not release communications port when user changes device link from enabled to disabled by writing to the #Enabled item.
  • 20533: Log file getting spammed with unnecessary messages on LOG_HIGH.

Enhancements:

  • 20534: Item added to allow user to monitor whether the device is still communicating or whether communications have stopped for a period of time (time is configurable).
MatrikonOPC Server forAllen Bradley PLCs Aug 27, 2016 4.0.2.6614 ​ Resolved Issues:
  • 20445: Individual Booleans do not read correctly
  • Several user manual issues were addressed. 
MatrikonOPC Condition Manager July 22, 2016 1.3.1 Resolved Issues:
  • 0020511: Matrix blocks Saturation and Rate Limit do not function.
MatrikonOPC Server for IEC 61850/61400-25 July 15, 2016 1.3.3_6593 New Features and Enhancements:
  • 20488: Add support for devices that use ASCE context identifier in indirect ref rather than MMS context identifier.
MatrikonOPC Server for SCADA DNP3  June 28, 2016 1.3.1_6591 Resolved Issues:
  • 0020504: OPC server returns write error and disconnects from PLC if a write is performed when configuration set to Arm Outputs (Select Before Operate).
MatrikonOPC Server for SCADA DNP3  April 28,
2016
1.3.0_6513 New Features and Enhancements:
  • Redundancy Group added to product. Please use this instead of Failover Channel for simple (non-load-sharing) redundancy.
Resolved Issues:
  • 0020461: OPC server can hang if configuration repeatedly reloaded.
MatrikonOPC Server for GDA Feb 16, 2016 3.0.1.6401
  • 0020406: GDA sending all 0s through stored procedure
MatrikonOPC Server for WITS Feb 04, 2016 1.0.1.6402
  • 0020169: Support adding items to pre-existing WITS records ("loose compliance")
MatrikonOPC Data Manager Jan 21, 2016 6.0.3.5.RC1
  • 0020365: ODM does not mark points that have failed to add in ReCreateGroup as not added to the group, so they die.
MatrikonOPC Redundancy Broker (ORB) Jan 21, 2016 4.2.1.6373
  • 0020386: ORB reporting incorrect status during failover
MatrikonOPC Server for FLEX Jan 14, 2016 2.1.0.6367
  • N/A
MatrikonOPC Server for Allen Bradley  Nov 04, 2015 4.0.1
  • 0020315: OPC server does not create O,I,S registers when initially reading configuration from .MTK file.
MatrikonOPC Data Manager Oct 30, 2015 6.0.3.4
  • 0020365: ODM points die if AddItems call fails when re-creating connections after connection failure (dead server).
OPC Server for PROVOX Direct Oct 16, 2015 1.3.0.4
  • 0019426: The OPC server now obtains DDP page numbers for all DDPs that are requested and only polls and DDP pages for items that are requested, instead of polling all possible DDP pages for each point for which DDPs are requested.
  • 0020190: The OPC server no longer requires specifying the controller name in the tag ID. The HDL name may also be omitted if it is the only HDL in the configuration. The permissible syntaxes are now HDL.Controller.Point.Tag, Controller.Point.Tag, and Point.Tag.
    Caution: This syntax should only be used when using only one PROVOX database and no redundant controllers or HDLs so that PROVOX point names are unique. To our knowledge, one plant commonly uses one database for all of its controllers.
  • 0020193: LCP OPP Status Mask Word and Status Word (SMSK and SWRD) can now be accessed bitwise by items MVPSTMSKx and MVPSTx where x is the bit number (1..16).
  • 0020194: Statistical (read-only) items NumberOfDDPsToPoll, NumberOfDDPsToValidate, NumberOfDDPsValid, NumberOfDDPsInvalid, NumberOfDDPsValidationFailed at Controller and Interface levels (Interface being an aggregate of all of its controllers) indicate how many DDP tags are being polled and how many need to be validated. DDP tags that are being polled will likely not obtain values until they are validated. This item can be used to estimate when DDP validation is finished and when reading of DDPs will commence (All requested DDPs must be validated before any are read).
  • 0020199: Statistical (read-only) item DDPsPollingAt at Point level is set to the time between receiving DDP messages for the last DDP page received (that is, the present time minus the last time at which that particular DDP page for that point was received). Values are given in milliseconds. This item can be used to estimate the responsiveness of DDP polls for that point.
  • 0020200: Provox Application Server syntax Tag.Bit is now supported for tags that already support bit fields by appending the bit number (for example, ALM.4 for ALM4).
  • 0020211: The OPC server allows for an adjustable delimiter as specified in registry parameter TagDelimiter. The value must be set to the DWORD number that is the ASCII value of the character you wish. For example, to set the delimiter to ‘/’, you would create a DWORD registry entry named TagDelimiter with the value 47. Default: ‘.’
  • 0020212: The OPC server now has an item at the HDL level called “DumpMessages60s” which, when it is written to, causes a brief description of each message sent by the OPC server to that HDL for the next 60 seconds to be logged to the log file. If the user wishes to log these messages for additional time, the item may be written to repeatedly, for example, once every 30 seconds, until the user does not wish these messages to keep being logged.
  • 0020213: The OPC server now has a feature which allows the OPC server to ignore demand OPP reads from clients if the point has been updated recently. Set the registry item “IgnoreOPPDemandReads” to the number of seconds of “staleness” required for the OPC server to permit demand reads on points. Default:0.
  • 0020214: FIRSTFAIL should support a larger value range. It is now a VT_UI2.
  • 0020231: Demand DDP reads should be higher priority than subscribed DDP reads but lower priority than DDP validation.
OPC Redundancy Broker (ORB) Sep 28, 2015 4.2.0
  • 0020339: Memory leak when a client such as ODM reads or writes using incrementing request IDs.
OPC Data Manager (ODM) Sep 28, 2015 6.0.3.3
  • 0020302: ODM compatability issue with ORB – OPC return calls.
  • 0020341: ODM does not clean up COM connection to OPC server due to outstanding OnShutdown callback.
OPC Redundancy Broker Sep 21, 2015 4.1.3
  • 0012680: An OPC client may hang on refresh2/demand read/lifetime if both OPC servers are waiting on watchdog tags.
  • 0015039: If ORB is disconnected from one of its servers at least 15 times in rapid succession while ODM is connected, ODM may terminate. 
  • 0017211: On certain operating systems (e.g., Windows 7, Windows 2008, Windows XP SP3 – Chinese Version), ORB cannot browse the network when configuring a redundant pair. Server ProgIDs can be manually entered. 
  • 0017329: When you configure a redundant pair to be HDA or AE exclusively, you will still be able to do DA calls.
  • 0017380: COM issues in ORB installation.
  • 0017379: A memory leak was observed when MatrikonOPC Data Manager is configured to perform DA writes to tags in an ORB redundant pair. A very small leak was also observed when Data Manager is configured to perform DA reads from an ORB redundant pair.
  • 0017399: When connecting to in-proc Servers, cannot be re-configured; needs "Standby becomes Primary ....".
OPC Data Manager (ODM) Aug 21, 2015 6.0.3
  • 0020301: ODM may deadlock due to thread interaction corrupting objects.
OPC Server for APACS Direct Aug 07, 2015 1.8.4
  • 0020266: Configuring redundancy at the APACS Network level can cause the OPC server to hang.
OPC Server for APACS Direct Jul 14, 2015 1.8.3
  • 0019501: An option is added to the server to suppress bad qualities from being reported when the program is updated on an APACS controller. Updates for these items are not sent to the OPC client. 
  • 0019502: Revalidation procedure time is improved by reducing the time that APACS Direct server takes to bring back controllers on line, following changes to the controller program. 
  • 0019900: Read error during re-optimize leads to some items never having valid data until a new re-optimize occurs. 
  • 0020132: OPC items qualities stay as bad after engineering changes are made to APACS controllers through 4-mation. 
  • 0020273: Revalidation causes items to go to Q_GOOD even if they are turned off.
OPC Server for Allen Brad June 29, 2015 3.2.1
  • 0020262: Support for PROSoft DH+ to Ethernet Gateway.
OPC Server for Bailey DCS June 11, 2015 1.4.1
  • 0020261: Checksum error communicating to ICI03 firmwares F and higher.
OPC Server for MOSCAD May 19, 2015 1.1.2
  • 0020234: Server stops polling on timeouts.
OPC Server for IP21 May 11, 2015 2.3.4
  • 0018911: IP21 Server Hang/Crash
OPC Server for SNMP May 01, 2015 2.0.7
  • 0020230: SNMP Unsigned 32 bit items (Integer32, Gauge32, Counter32) are not the correct type (are VT_I4; should be VT_UI4) and do not write correctly (always write 0 regardless of the value written).
OPC Server for Siemens PLCs Apr 27, 2015 1.3.2
  • 0019543: Importing large S7 projects crash server.
OPC Server for JCN1 Mar 24, 2015 1.2.2
  • 0020149: Support communications to 2 or more N1 devices on the same Ethernet address (but separate ARCNET addresses).
OPC Server for Vestas Feb 20, 2015 2.1.1
  • 20167: Support for 2-byte NEG Micon turbine numbers (0-65535).
OPC Server for IP21 Dec 05, 2014 2.3.3
  • 0020089: Read At Time doesn't function As expected when Multiple tags are queried in single call.
OPC Server for GE Turbines Nov 28, 2014 3.0.9 Mark VI Direct now supports all known types of GE Turbines alarms and Events for Mark VI Turbines (not Mark VIe turbines). 

Specifically:
  • 0019807: Support Alarm/Event type “SOE” in GE Mark VI.
  • 0019817: Support Alarm and Hold Lock/Unlock Operations in GE Mark VI.
  • 19818: Support Alarm/Event type "Hold" in GE Mark VI.
  • 0019819: Mark VI Direct Alarms and Events now use the same A&E format as Mark V Direct: Source = Connection.Turbine/Signal Message = Description { Drop : State : Acked : Reset : Locked : Signal }
  • 0020078: Support acknowledging Holds using a DA item
OPC Server for IP21 Oct 28, 2014 2.3.1 Matrikon OPC Server for IP21 installer doesn't launch with "Run as Administrator" by default on Operating Systems Windows 7 and above.